What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CENTER TANK AFT TOP SKIN PANEL AT STA 857, BL 46 RIGHT, 2 FORWARD OF REAR SPAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED COMMODORE DER ENGINEERING SKETCH NR EAF-MIA- 99-03-17-002 . (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).