What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, WING, SKIN, AT SCREEN HOLE RT WING O/B L/E I/B SEGMENT AT STA XFS 676.756 AT FRONT SPAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER AND FILLER IAW DC8 SRM 57-2-0 FIG 38 AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).