What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BILGE UPPER CAP UNDER NUT PLATE AND WEB AT STA 1306, BETWEEN LONGERONS 34 LEFT AND LONGERON 34 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-0 AND 53-02-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).