What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, LT ELEVATOR, 3 SPOTS BETWEEN STA XE259 AND STA XE 269. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FINGER DOUBLERS TO TRAILING EDGE IAW DC8 SRM 51-1-1 TABLE B AND 51-1-2. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).