What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, LONGERON 33 RIGHT END TIE FITTING AT STA 8.00. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW FAA APPROVED TENNESSEE TECHNICAL SERVICES DER ENGINEERING SKETCH NR 99 085. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).