What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ATTACH ANGLE, FRAME AT STA 360, AFT SIDE ABOVE BETWEEN LONGERONS 31 RIGHT AND LONGERON 29 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW FAA APPROVED TENNESSEE TECHNIDAL SERVICES DER ENGINEERING SKETCH NR 99-085. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).