What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, SPLICE, LONGERON 36, BETWEEN STA 1726 AND STA 1745. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR SPLICE AND LONGERON SECTION IAW DC8 SRM 53-2-9, 51-1-2 AND 51-1-22. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).