What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 1420, BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SECTION AND SPLICE REPAIR IAW DC8 SRM 53-2-3 FIG 14. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).