What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BULKHEAD, ON FWD BULKHEAD, IN R/MLG W/W AT STA 870, BL 30 RIGHT, WL 10 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REAR SPAR TO FUSELAGE ANGLE REPAIR IAW DC8 SRM 53-2-5 PG 16. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).