What was found
DURING A MAINTENANCE VISIT, FOUND AFT LOWER CARGO COMPT BULKHEAD BETWEEN PIT CENTER PANEL NEEDS REPAIR CRACKED AT STA 1340. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PARTITION IAW DAC DWG NR 99-085-1 AND IAW FAA APPROVED TENNESSEE TECHNICAL SERVICES DER ENGINEERING SKETCH NR EO-99-094 WITH APPROVED 8110-3 DATED JUNE 11, 1999.