What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, FLOOR SUPPORT, AT LOCATION Y600, BETWEEN LONGERONS 33 RIGHT AND LONGERON 36. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FLOOR SUPPORT IAW DAC DWG 5707967 AND DC8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).