What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, WEB, BETWEEN STA Y920 AND SAT Y940, AT LONGERON 22 RIGHT, BL 60 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED WEB IAW FAA APPROVED DER ENGINEERING SKETCH NR DH SK-087-089 APPROVED 8110-3. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).