What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, TO BRACKET AT STA 1165, BETWEEN LONGERONS 29 RIGHT AND LONGERON 30 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW BRACKET IAW DC8 SRM 51-1-4. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).