What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, TO FITTING AT STA 560, BETWEEN LONGERONS 33 LEFT AND 34 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW FITTING AND INSTALLED IAW DC8 SRM 51-1-20. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).