What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ON FINGER DOUBLER ANGLE BETWEEN STA 960 AND STA 980 -43 LBL, AT WL 10 RIGHT, BELOW NR 2 SEAT TRACK, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED AND REPLACED FINGER DOUBLER ANGLE IAW DC8 SRM 51-1-20D AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).