What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, AFT PIT FRAME AT STA 1500 AND LONGERON 26 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FRAME REPAIR IAW DC8 SRM 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).