What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, WHEEL WELL ANGLE FITTING TOP OF W/W AT STA 980, BL 46 LEFT AND WL 10 RIGHT, BELOW SEAT TRACK. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING AND REPAIR ANGLES IAW DC8 SRM 51-1-4 AND 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).