What was found
DURING A MAINTENANCE VISIT FOUND CRACK, RIGHT WING, L/E RIBS AT STA XFS 703.75, XFS 672.5, XFS 566.25, XFS 585, XFS 591.25, XF 603.75, XFS 622.5, XFS 635. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS AND INST IAW DC8 SRM 57-2-0 FIG 2.