What was found
DURING A MAINTENANCE VISIT, FOUND FORWARD CARGO COMPARTMENT TWO FITTINGS AT APPROX STATION 300 AND 320, STRINGER RT 33, DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTINGS IAW DC-8 53-2-0 FIGURE 2D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).