What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO ATTACH ANGLE AT STATION 1219 AND LONGERON 27 LT. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED REPAIR AS PER SRM 57-2-0, PAGE 20 AND FIG 2. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).