What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO L ANGLE AT STA 1040, BL 14L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW DC-8 SRM 53-4-1, FIG 35, AND 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).