What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 1040 TO 1060, BL 17L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLES IAW DC-8 SRM 53-2-0 FIG 1B AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).