What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING IN AFT PIT AT STA 1450 BL 25R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. DRILLED AND INSTALLED NEW FITTING IAW DC8 SRM 51-3-2, 53-4-1 FIG 44C, AND 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).