What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO GILLINER ATTACH ANGLE AT STA 1220 BL 27R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ATTACH ANGLE IAW DAC DWG 5750725, DC8 SRM 51-1-3 AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).