What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SEAT TRACK A RIGHT TUNNEL AT STA 1100, X+59 TO +62, Z+1.1 TO +1.3. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SPLICE AND DOUBLER IAW DC8 SRM 53-2-3. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).