What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO T-BOX FITTING IN AFT PIT AT STA 1445 BL 30R TO 31R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).