What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO INTERCOSTAL AT STA 340 TO 348 BL 35L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW INTERCOSTAL IAW DC8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).