What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FORWARD PIT FRAME AT STA 220 BL 34R TO 33R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FRAME SPLICE IAW DC8 SRM 53-2-0 FIG 2, 51-1-20D, AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).