What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION ON C-3 DOOR BACKUP FITTING AT STA 1195, LONG 30R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. REPLACED FITTING WITH REPAIR FITTINGS IAW DC8 SRM 53-2-0 FIG 2D (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)