What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION EMITTING FROM NUT PLATES ON FRAME CAP AT STA 1540, ABOVE 33L. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED FILLER, -15 FILLER AND -13 ANGLE. DRILLED NEW CAP IAW DC8 SRM 51-1-24. INSTALLED IAW RED-05214. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)