DURING A MAINTENANCE VISIT, FOUND CORROSION ON T ANGLE IN AFT PIT AT STA 1060 TO 1080, LONG 35L. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED NEW ANGLE IAW DC8 SRM 51-1-8, 51-1-22, AND DAC DWG 9758507. TO BE INSTALLED ON N/R 40776. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)