What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION ON Z FITTING IN AFT PIT AT STA 1230, LONG 33R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. REMOVED AND REPLACED WITH NEW Z FITTING IAW DC8 SRM 53-2-0 FIG 2D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)