What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION ATTACH POINT ON RT FRAME ATTACH FITTING AT STA 120, BL 21R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. DRILLED NEW FITTING IAW DAC DWG 4597643 AND DC8 SRM 51-3-2. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)