What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION ON KEEL BEAM, TOP AREA, AT STA 960 TO 940, X+6, Z-45. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW DAC DRG 5892159 AND DC8 SRM 53-2-0, 51-1-21, AND 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)