What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LONGERON 24 RIGHT BETWEEN STA 857 TO STA 980, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW LONGERON 24 RIGHT IAW TIMCO WORKCARD 90453100. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).