What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO SEAT TRACK BETWEEN STA 180 TO STA 185 AND BL 65 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW SEAT TRACK IAW DC-8 SRM 51-3-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).