What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING AT STA 822 BETWEEN LONGERONS 21 RIGHT AND 22 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC-8 SRM 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).