What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FITTING BETWEEN STA 1525 TO STA 1530 AND LONGERON 31 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).