What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO BULKHEAD WEB AND FITTING BETWEEN STA -12 TO STA -32 AND LONGERON 23 LEFT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW WEB AND FITTING IAW SRO 8530026. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).