What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, CEILING ATTACH ANGLE, AT STA=500, BETWEEN BL= -10 AND BL= +10, AT WL= -5. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC8-SRM. FABRICATED NEW ATTACH ANGLE AND INSTALLED IAW FAA APPROVED DAC DWG NR 5707961. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM)