What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, UNDER NUTPLATE, AT STA= 440, BL= 40 RIGHT, WL= -1 WEB HAS CORROSION. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW FAA APPROVED DC-8 SRM 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).