DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, VERTICAL SIDEWALL INTERCOSTAL, AT STA=460, JUST ABOVE LONGERON 27 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM. FABRICATED NEW INTERCOASTAL AND INSTALLED IAW FAA APPROVED DAC DWG NR 3610417. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).