What was found
DURING A MX VISIT, FOUND DRILL DAMAGE, INCLUDING DOUBLE HOLES AND HOLES IN THE RADIUS, ON THE FRAME, STA= 520 AT LONGERON 20 LEFT AND BETWEEN LONGERONS 6 RT TO LONGERON 9 RT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. AT LONGERON 20 LEFT, FABRICATED AND INSTALLED ANGLE; BETWEEN LONGERONS 6 RIGHT TO 7 RIGHT, FABRICATED AND INSTALL REPAIR ANGLE; AND BETWEEN LONGERONS 8 RIGHT AND 9 RIGHT, FABRICATED AND INSTALLED A FLUSH BUSHING AND ANGLE; ALL IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR RE0-05591.