What was found
IN FLT, LEFT ENG FUEL LOW PRE LT ILLUM. MOMENTARILY AND WENT OUT. A SLIGHT FUEL SMELL WAS DETECTED. ON DESCENT WHEN APU STARTED, A STRONG FUEL SMELL FILLED CABIN-SHUT APU DOWN. OPERATIONAL CHECK OF #1 ENGINE WITH NO DEFECTS NOTED.APU ECU NOTED NO START EVENT PRIOR TO SUCCESSFUL START IN FLT. APU GROUND START AND OPERATION CHECK GOOD WITH NO FUEL SMELL.