What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, FRAME ATTACH ANGLE, STA= 480 ABOVE LONGERON 26 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM. REMOVED CORROSION IAW DC-8 SRM 51-1-8 (SUPPORT ANGLE) AND DC-8 SRM 53-2-0 FIG 1-F; DAC DWG NR 3706754-502 (GUSSET). (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).