What was found
EVIDENCE OF LIGHNTING STRIKE AT FS 224.870 (24.5") LBL 14.5. INSTALLED DOUBLER REPAIR AT FS 224.870 AS PER B757 SRM 53-00-01 FIG 201. IAW AVBORNE RES 26449-2, DATED 09/14/06 AND 8110-3 DATED 9/14/06. MATERIAL USED FOR DOUBLER 2024-T3 .071 SIZE OF REPAIR 4.5 X 4.75 INCHES PO 28928. MATERIAL USED FOR FILLER 2024-T .063, .75 INCH DIAMETER, PO 028652.