As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ACCOMPLISHMENT OF FCD 33-08, FOUND NUMEROUS UPPER EMERGENCY FLOOR TRACK SECTIONS WITH WARPED, CRACKED AND BROKEN AREAS. EMERGENCY FLOOR TRACK LIGHTING SYSTEM BATTERIES FAILED CAPACITY CHECK. REPLACED DAMAGED SECTIONS PER AMM 33-21-27. REPLACED EMERGENCY FLOOR TRACK LIGHTING BATTERIES PER MM 33-21-27. SYSTEM OPERATIONAL CHECKED GOOD.