What was found
SMOKE LAV DETECTOR FAULT LOCATION 38. PLACED ON MEL 26-17-01A. REPLACED SMOKE DETECTOR, OPS NORMAL IAW AMM 26-17-15-400-801-A. THIS CLEARS DMI 2225 PLACARDS REMOVED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SMOKE LAV DETECTOR FAULT LOCATION 38. PLACED ON MEL 26-17-01A. REPLACED SMOKE DETECTOR, OPS NORMAL IAW AMM 26-17-15-400-801-A. THIS CLEARS DMI 2225 PLACARDS REMOVED.