As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON POSTFLIGHT NOTICED RIGHT MAIN GEAR TRUNNION PANEL (DOOR) BENT. ACCOMPLISHED TEMP (INTERIM) REPAIR IAW DER ENGINEERING DRAWING 52-12548-1, 8110-3 APPROVAL DATED 22 NOV 2012. REPETITIVE INSPECTIONS AT A CHECK INTERVALS AND PERMANENT REPAIR AT C CHECK.