As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RUDDER DOES NOT FULL DEFLECT TO RT . RUDDER & RUDDER TRIM SYSTEM RIG CHECK FOUND CONTROL CABLE TENSION WAS OUT OF LIMIT. PERFORM RUDDER AND RUDDER TRIM CONTROL SYS ADJ IAW 27-21-00. PERFORM RUDDER TRIM SYS TEST NML. EON 744-27-632292-0017 R1 IS ISSUED TO PERFORM ONE TIME INSPECTION OF RUDDER CABLE TENSION FOR 744F FLEET.5. ALL THE INSPECTION RESULTS WILL BE PROVIDED TO BOEING FOR FURTHER INVESTIGAT.